CON 700

Product Description

pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample

The selection of a suitable electrode depends on the types of application

Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable

Single Junction

Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers

Double Junction

Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes

Sealed(gel-filled)

No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required

Refillable

Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low

Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses

pH Electrodes (General Glass) & (General Plastic)

 

Description

  • Large screen that displays Conductivity or TDS readings with Temperature in ºC or ºF
  •  Ready indicator let you know when readings are stable
  •  Selectable cell constant
  • Auto-ranging across 5 Conductivity and TDS ranges
  • Up to 5-point push button calibration
  • Non-volatile memory holds up to 100 data points
  • Integral electrode holder

Product Description

Product Specification Description
Conductivity Range 0.01 to 200.0 mS/cm
Resolution/ Accuracy 0.01 μS; 0.1 μS ; 1 μS ; 0.01 mS ; 0.1 mS  ; ±1% full scale
TDS Range 0.01 to 100 ppt @ 0.5 TDS factor (to 200 ppt @ 1.0 TDS factor)
Resolution / Accuracy 0.01 ppm; 0.1 ppm ; 1 ppm ; 0.01 ppt ; 0.1 ppt  ; ± 1% full scale + 1 digit
Calibration Points
(Cond. / TDS)
5  points
Temperature Range 0.0 to 100.0 0C / 32.0 to 212.0 0F
Resolution/Accuracy 0.1 0C / 0.1 0F ; ± 0.5 0C / ± 0.9 0F
Built-in Electrode Arm Yes
Temperature Coefficient 0.00 to 10.00 %
Temperature Normalization 15 to 30 °C/ 59.0 to 86.0 0F
Memory 100 Data sets
Electrode Included, ultem body ECCONSEN9501D,cell constant 1.0, 1 m cable
Power Requirement Included, 100 /240VAC SMPS Power Adapter with US/UK/EUR/Japan plug  ,9V,6W, CENTRE +ve
Dimensions
(L x W x H)
Meter 17.5 x 15.5 x 6.9 cm
Boxed 30.8 x 23.5 x 12.4 cm
Weight Meter 650 g
Boxed 1800 g

Ordering Information

Order No. Item
ECCON70043S Eutech CON 700 Meter With Conductivity/ATC Probe CONSEN9501D ,K=1.0 , Integral Electrode Holder & 100/240 VAC Adapter
93X546101 2-Cell Conductivity/ATC Electrode, 0.1 cell constant, SS Sensor, Epoxy-Body (700 & 2700 series)

Conductivity Calibration Solutions

Order No. Item
ECCON100BT 100 μS KCL, 480 ml
ECCON500BT 500 μS KCL, 480 ml
ECCON1413BT 1413 μS KCL, 480 ml
ECCON2764BT 2764 μS KCL, 480 ml
ECCON5000BT 5.0 mS KCL, 480 ml
ECCON1288BT 12.88 mS KCL, 480 ml
ECCON1118BT 111.8 mS KCL, 480 ml

TDS Calibration Solutions

Order No. Item
EC44250BT 50 ppm, 480 ml
EC442300BT 300 ppm, 480 ml
EC4421000BT 1000 ppm, 480 ml
EC4423000BT 3000 ppm, 480 ml

Download Brochure

• Eutech 700 Series Family Brochure