pHTestr10 BNC

Product Description

pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample

The selection of a suitable electrode depends on the types of application

Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable

Single Junction

Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers

Double Junction

Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes

Sealed(gel-filled)

No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required

Refillable

Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low

Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses

pH Electrodes (General Glass) & (General Plastic)

 

SKU: f001-1-1-2-1-3-1-1-1-2-1-2-1-1-1-1-1-1-2-1-2-1-1 Categories: ,

Description

  • Compact, lightweight waterproof design; even floats
  • Large display screen for enhanced readability
  • Important functions such as mode, battery level are displayed on LCD screen for convenience
  • Multi-electrode compatibility via BNC connector
  • Auto-off: saves batteries
  • Hold function to freeze the reading at a point of time and more
  • Self – diagnostic messages
  • Auto buffer recognition
  • 3 point push button calibration, selectable USA or NIST buffer standards

Product Description

Product Specification Description
Waterproof Yes
pH Range -1.00 to 15.00 pH
Resolution/Accuracy 0.01 pH / ± 0.01 pH
Calibration Up to 3 points
(USA; pH 4.01, 7.00, 10.01 or NIST ; pH 4.01, 6.86, 9.18)
Temp.Display 0-50.0°C / 32.0-122.0°F
Temp. Resolution 0.1°C / 0.1 °F
ATC MTC
Operating Temp. 0 – 50 °C
Electrode To be ordered separately
Power Requirement 4 x 1.5 V “A 76” Alkaline Batteries
Dimensions
(L x W x H)
Tester 16.5 x 3.8 cm
Boxed 22 x 6 x 5 cm
Weight Tester 90 g
Boxed 170 g

Ordering Information

Order No. Item
PHTEST10BNC Waterproof pHTestr 10 BNC Tester with MTC; BNC connector sensor; ±0.01 pH resolution (meter only – electrode to be ordered separately)
ECFC7252101B General- purpose plastic body single junction gel-filled pH combination electrode, 12×90 mm, 1m cable length
ECFG7350401B Glass-body pH combination electrode, annular ceramic reference junction with protective sensor guard,1m cable length

pH Calibration Solutions

Order No. Item
ECBU4BTC pH 4.01 buffer, 480 ml
ECBU7BTC pH 7.00 buffer, 480 ml
ECBU10BTC pH 10.01 buffer, 480 ml
EC-BU-6.86BT pH 6.86 buffer, 480 ml
EC-BU-9.18BT pH 9.18 buffer, 480 ml