DO 2700

Product Description

pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample

The selection of a suitable electrode depends on the types of application

Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable

Single Junction

Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers

Double Junction

Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes

Sealed(gel-filled)

No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required

Refillable

Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low

Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses

pH Electrodes (General Glass) & (General Plastic)

 

SKU: f001-1-1-2-1-3-1-1-1-2-1-2-1-1-1-1-1-1-2-1-2-2-1 Categories: ,

Description

  • Measures Dissolved Oxygen in % saturation, ppm, mg/L at ± 0.5 % full scale accuracy
  • Automatic calibration at 100 % and independent 0 % – greater measurement sensitivity during low oxygen levels
  • Accurate readings in varying conditions with Temperature, Salinity and Barometric Pressure Compensation
  • Non-volatile memory holds up to 500 data points – time and date-stamped for GLP compliance
  • Bi-directional RS232 for easy data transfer to computer
  • Cal-due alarm – no more out-dated calibrations!
  • Auto-logging function for convenient continuous monitoring
  • Limit alarm alerts when reading falls out of range
  • Password protection for setup and calibratio

Product Description

Product Specification Description
Dissolved Oxygen Range 0.00 to 50.00 mg/L
Resolution/Accuracy 0.01 ppm (mg/l) ; ± 0.5% full scale
Range (% saturation) 0 to 600.0 %
Resolution/Accuracy 0.1 % ; ± 0.5 % full scale
Automatic Barometric Pressure Compensation 450 to 825 mm Hg
Resolution/Accuracy 1 mmHg ; Manual input
Temperature Range 0.0 to 50.0 0C / 32.0 to 122.0 0F
Resolution/Accuracy 0.1 0C (0.1 0F); ± 0.3 0C (± 0.5 0F)
Salinity Correction 0 to 50 ppt
Resolution 0.1 ppt
GLP Yes
Memory 500 data sets
Output RS 232C (via cable)
Electrode Included, Self-stirring DO electrode EC620SSP
Power Requirements Included, 100 /240VAC SMPS Power Adapter , 9V,6W
Dimensions
(L x W x H)
Meter 17.5 x 15.5 x 6.9 cm
Boxed 30.8 x 23.5 x 12.4 cm
Weight Meter 650 g
Boxed 1800 g

Ordering Information

Order No. Item
ECDO270042 DO 2700 Meter With Self-Stirring Dissolved Oxygen / BOD Electrode (EC620SSP), RS232C Cable & 100/240 VAC Adapter, RS232 cable

Zero Oxygen Solution

Order No. Item
ECDOZEROSOLN Zero Oxygen Solution, 0% DO, 480 ml