Autoclaves (Vertical Type)

Autoclaves (Vertical Type)

Product Description

pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample

The selection of a suitable electrode depends on the types of application

Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable

Single Junction

Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers

Double Junction

Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes

Sealed(gel-filled)

No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required

Refillable

Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low

Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses

pH Electrodes (General Glass) & (General Plastic)

 

SKU: f001-1-1-2-1-3-1-1-1-2-1-2-1-1-1-1-1-1-2-1-2-2-2-1-1-2-1-1-1-1-1-1-1-1-1-1 Categories: ,

Description

Microprocessor control with reliable safety functions guarantees optimum sterilization temperature

Performance
  • Microprocessor controller and temperature calibration function allows for high precision temperature control
    • Sterilization temperature at 110 to 123°C
    • Melting* temperature at 60 to 100°C

Liquefaction of coagulated agar media

  • Automatic sterilization system for unattended operation
    • Heating > Check safe > Sterilization > Sterilization safe > Exhausting > End
  • Convenient operation modes for various uses
    • Standard modes and program modes are listed in detail as below tables
  • Temperature calibration function
Convenience
  • Conveniently monitored by an independent control display, sterilization process display, and pressure gauge
    • VFD for visualization of temp, pressure (optional), timer, warning alert checks
    • LED lamps for sterilization process check
    • Easy pressure check with the standard gauge attached to the front
  • Vertical type autoclaves which allow for top loading are suitable for high volume sterilization
    • Baskets are stackable two high or even more levels, which secure inside the chamber space requirements
  • Low-maintenance
    • The chamber is constructed of stainless steel which is superiorly resistant to corrosion
    • Easy to replace silicone gasket
  • Convenient documentation with the optional data recorder
    • Dot type recorder(6 point) allows for precise documentation
Safety
  • Mechanical safety devices
    • Over current protection
    • Over temperature protection by automatic power cutoff
    • Over pressure protection by automatic and manual safety valve
  • Safety warning systems
    • Over temperature warning
    • Low temperature warning
    • Low water level warning
    • Low heat warning if the temperature does not reach the sterilization or melting temperature
    • Sterilization fail warning if the operation is unexpectedly stopped during sterilization process
  • Slide opening door with plastic cover of low thermal conductivity prevents burns from the contact

Product Description

Model ST-50G ST-65G ST-85G ST-105G
Control Microprocessor PID control
Chamber volume (L/cu ft) 50/1.8 65/2.3 85/3.0 105/3.7
Temperature 1) Sterilization temp. (℃/℉) 110 to 123/198 to 221.4
Melting temp.(℃/℉) 60 to 100/108 to 180
Pressure Sterilization at 121℃ (kg/cm 2) 1.1 to 1.2
Gauge range in analog (Mpa) – 0.1 to 0.6
Safety Over temperature protector/Pressure safety valve/Over current protector
Warning alert (over temp./low temp./low heat/sterilization fail/low water level)
Timer 0 to 999 min.
Dimension No. of baskets (standard / max.) 2/2 2/2 2/2 2/2
Load per baskets (Kg / lbs) 10 / 22.0
Basket (OxH) (mm / inch) 380×180/14.9×7.1 380×230/14.9×9.1 380×330/14.9×13.0 380×405/14.9×15.9
Interior (WxH) (mm / inch) 400×458/15.7×18.0 400×558/15.7×21.9 400×758/15.7×29.8 400×908/15.7×35.7
Exterior (W×D×H) (mm / inch) 624x672x870/24.6×26.5×34.2 624x672x971/24.6×26.5×38.2 624x672x1083/24.6×26.5×42.6 624x672x1233/24.6×26.5×48.5
Exterior with exhaust tank
(W×D×H) (mm / inch)
722x672x870/28.4×26.5×34.2 722x672x971/28.4×26.5×38.2 722x672x1083/28.4×26.5×42.6 722x672x1233/28.4×26.5×48.5
Net weight (Kg / lbs) 94.5/208.3 99.5/219.4 104/229.3 110/242.5
Electrical requirements
(230V, 50/60 Hz)
14.3A 14.3A 14.3A 21.3
Cat. No. AAHL1015K AAHL1025K AAHL1035K AAHL1045K

 

Ordering Information

Order No. Item
AAHL1015K ST-50G Autoclave , 230V, 50/60Hz
AAHL1025K ST-65G Autoclave , 230V, 50/60Hz
AAHL1035K ST-85G Autoclave, 230V, 50/60Hz
AAHL1045K ST-105G Autoclave, 230V, 50/60Hz

 

Standard accessories

• Baskets (2ea), Heater cover, Exhaust tank, Drain bucket

Optional accessories (Refer Brochure)

• Pressure sensor, Recorder