Mini Incubator

Mini Incubator

Product Description

pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample

The selection of a suitable electrode depends on the types of application

Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable

Single Junction

Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers

Double Junction

Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes

Sealed(gel-filled)

No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required

Refillable

Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low

Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses

pH Electrodes (General Glass) & (General Plastic)

 

SKU: f001-1-1-2-1-3-1-1-1-2-1-2-1-1-1-1-1-1-2-1-2-2-2-1-1-2-1-1-1-1-1-1-1-1-1-1-1-1-1-1 Categories: ,

Description

Compact design for efficient lab space use

Maximum 8 micro plates can be inserted to inner chamber for ELIS

Performance
  • Temperature range from ambient +5 to 650C
  • Microprocessor PID feedback control of the heater and the fan ensuring temperature uniformity
  • Automatic temperature calibration
Convenience
  • Ease-of-operation provided by a bright VFD (vacuum fluorescent display), responsive touch buttons, and a jog dial
  • Wire shelves are provided for space saving of inner chamber Maximum 4 wire shelves supporting 8 micro plates is especially suitable for ELISA
  • Push buttons for easy opening of door.
  • Transparent polycarbonate window providing a clear view of the chamber interior
  • Compact design for space saving of laboratory of the chamber interior
Safety
  • Open door alarm
  • Over-temperature protection, Over-current protection

Product Description

Model IM-10
Temperature Range (℃ / ℉) Amb. +5 to 65 / Amb. +9 to 149
Fluctuation at 37℃ (±℃ / ℉) 0.5 / 0.9
Variation at 37℃ (±℃ / ℉) 0.5 / 0.9
Dimension (W×D×H) Volume (L / cu ft) 10 / 0.4
Interior (W×D×H) (mm / inch) 278 x 262 x 160 / 11 x 10.4 x 6.3
Exterior (W×D×H) (mm / inch) 400 x 410 x 264 / 15.7 x 16.1 x 10.4
No. of wire shelf (standard / max.) 2 / 4
Net weight (Kg / lbs) 12.8 / 28.2
Electrical requirements (230V, 50 / 60Hz) 1.0A
Cat. No. AAH24315K

Ordering Information

Order No. Item
AAH24315K IM-10 Mini Incubator, 230V, 50/60Hz

Standard Accessories

• Wire shelves (2ea)

Optional Accessories (Refer Brochure)

• Perforated shelves