Chemical Oxygen Demand (COD) Tubetests

///Chemical Oxygen Demand (COD) Tubetests

Chemical Oxygen Demand (COD) Tubetests

Product Description

pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample

The selection of a suitable electrode depends on the types of application

Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable

Single Junction

Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers

Double Junction

Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes

Sealed(gel-filled)

No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required

Refillable

Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low

Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses

pH Electrodes (General Glass) & (General Plastic)

 

SKU: f001-1-1-2-1-3-1-1-1-2-1-2-1-1-1-1-1-1-2-1-2-2-2-1-1-2-1-1-1-1-1-1-1-1-1-1-1-1-2-2-1-1-1-3-1-1-1-2-1-1 Categories: ,

Description

The Palintest range of tubetests® reagents offer pre-dispensed reagents for COD  for ease of use

Pre-prepared liquid reagents ,Tube tests range covering nutrient-based parameters such as COD. These reagents are used with Palintest Photometers and include sample/method preparation steps utilizing additional  accessories such as digestion/heater blocks which need to be purchased separately.

Product Description

Chemical Oxygen Demand (COD)

Mercury Free for Low Chloride Samples

PL 450 COD/150 Tubetests/Mercury Free (25 tests) Range 0 – 150 mg/l
PL 452 COD/400 Tubetests/Mercury Free (25 tests) Range 0 – 400 mg/l
PL 453 COD/1000 Tubetests/Mercury Free (25 tests) Range 0 – 1000 mg/l
PL 454 COD/2000 Tubetests/Mercury Free (25 tests) Range 0 – 2000 mg/l
PL 456 COD/20000 Tubetests/Mercury Free (25 tests) Range 0 – 20000 mg/l

Containing Mercury for Moderate Chloride

PL 460 COD/150/M Tubetests with Mercury (25 tests) Range 0 – 150 mg/l
PL 462 COD/400/M Tubetests with Mercury (25 tests) Range 0 – 400 mg/l
PL 463 COD/1000/M Tubetests with Mercury (25 tests) Range 0 – 1000 mg/l
PL 464 COD/2000/M Tubetests with Mercury (25 tests) Range 0 – 2000 mg/l
PL 466 COD/20000/M Tubetests with Mercury (25 tests) Range 0 – 20000 mg/l

Containing Mercury for High Chloride Samples

PL 461 COD/150/2M Tubetests with Mercury (25 tests) Range 0 – 150 mg/l
PL 468 COD/1000/M Tubetests with Mercury (25 tests) Range 0 – 1000 mg/l
PL 465 COD/2000/2M Tubetests with Mercury (25 tests) Range 0 – 2000 mg/l
PL 467 COD/20000/2MTubetests with Mercury (25 tests) Range 0 – 20000 mg/l

COD Standard Solutions

PL 470 COD Standard Solution Range 80.0 mg/l
PL 472 COD Standard Solution Range 250 mg/l
PL 474 COD Standard Solution Range 800.0 mg/l
PL 476 COD Standard Solution Range 10,000 mg/l