CON 2700

Product Description

pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample

The selection of a suitable electrode depends on the types of application

Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable

Single Junction

Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers

Double Junction

Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes

Sealed(gel-filled)

No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required

Refillable

Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low

Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses

pH Electrodes (General Glass) & (General Plastic)

 

Description

  • Choose auto-calibration with preset values for quick easy calibration, or manual multi-point calibration for greater accuracy
  • Easy standardization with auto-standardization feature – detect the exact cell constant value of your electrodes with the press of a button
  • Quick, easy electrode diagnosis with the effective cell constants display
  • Replatinization in 5 minutes with the built-in replanitization circuit
  • Non-volatile memory holds up to 500 data points – time and date-stamped for GLP compliance
  • Bi-directional RS232 for easy data transfer to computer
  • Cal-due alarm – no more out-dated calibrations
  • Auto-logging function for convenient continuous monitoring
  • Limit alarm alerts when reading falls out of range
  • Password protection for setup and calibration

Product Description

Product Specification Description
Conductivity Range 0.050 μS to 500.0 mS
Resolution/Accuracy 0.01 / 0.1 μS ; 0.001 / 0.01 / 0.1 mS  ; ±1 % full scale
Resistivity Range 2.000 Ω to 20.0 MΩ
Resolution/Accuracy 0.01 / 0.1 Ω ; 0.001 / 0.1 kΩ ; 0.01 MΩ ; ±1 % full scale
Salinity Range 0.0 to 80.0 ppt
Resolution/Accuracy 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt  ; ±1 % full scale
TDS Range 0.050 ppm to 500 ppt (@ TDS factor 1.00)
Resolution/Accuracy 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt ; ±1 % full scale
Calibration Points TDS/Conductivity 5 points
Temp. Range 0.0 to 100.0 0C / 32.0 to 212.0 0F
Resolution/Accuracy 0.1 0C (0.1 0F) ; ± 0.3 0C( ± 0.5 0F)
Temp. Coefficient Linear & pure ; 0.000 to 10.000 %
Normalization Temperature 15.0 to 30.0 0C (59.0 to 86.0 0F)
Built-in Electrode  Arm Yes
Compensation ATC / MTC
GLP Yes
Memory 500 data sets
Output RS 232C (via cable)
Electrode Included, 4 cell epoxy body Conductivity electrode, CONSEN9201D, K=0.530, 1 m cable
Power Requirements Included, 100 /240VAC SMPS Power Adapter , 9V,6W
Dimensions
(L x W x H)
Meter 17.5 x 15.5 x 6.9 cm
Boxed 30.8 x 23.5 x 12.4 cm
Weight Meter 650 g
Boxed 1800 g

Ordering Information

Order No. Item
ECCON270043S Eutech CON 2700 Meter With 4-Cell Conductivity Probe CONSEN9201D K=0.530, Integral Electrode Holder & 100/240 VAC Adapter, RS232 cable
93X546101 2-Cell Conductivity/ATC Electrode, 0.1 cell constant, SS Sensor, Epoxy-Body (700 & 2700 series)

Conductivity Calibration Solutions

Order No. Item
ECCON100BT 100 μS KCL, 480 ml
ECCON500BT 500 μS KCL, 480 ml
ECCON1413BT 1413 μS KCL, 480 ml
ECCON2764BT 2764 μS KCL, 480 ml
ECCON5000BT 5.0 mS KCL, 480 ml
ECCON1288BT 12.88 mS KCL, 480 ml
ECCON1118BT 111.8 mS KCL, 480 ml

TDS Calibration Solutions

Order No. Item
EC44250BT 50 ppm, 480 ml
EC442300BT 300 ppm, 480 ml
EC4421000BT 1000 ppm, 480 ml
EC4423000BT 3000 ppm, 480 ml

Salinity Calibration Solutions

Order No. Item
ECNACL5PPT 5 ppt Nacl, 480 ml
ECNACL25PPT 25 ppt Nacl, 480 ml
ECNACL45PPT 45 ppt Nacl, 480 ml

Download Brochure

• Eutech 2700 Series Family Brochure