EcoTestr EC High

Product Description

pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample

The selection of a suitable electrode depends on the types of application

Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable

Single Junction

Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers

Double Junction

Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes

Sealed(gel-filled)

No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required

Refillable

Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low

Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses

pH Electrodes (General Glass) & (General Plastic)

 

Description

  • IP67 waterproof, floats on water for easy retrieval
  • Easy-to-use, gives fast and accurate readings
  • LCD Display 3½ digit with annunciator
  • Accuracy ± 1% of Full scale
  • Auto shut-off to conserve battery life
  • Automatic Temperature Compensation
  • Click-lock battery compartment – no tools required to change batteries
  • Other features include hold function, automatic calibration

Product Description

Product Specification Description
Waterproof Yes
Range 0.10-19.90 mS/cm
Resolution/Accuracy 0.10 mS/cm; ± 1% of full scale
ATC Yes
Temp. Display N.A
Calibration Points 1 point
Electrode Type 2-pin Stainless Steel
Power Requirement 4 x 1.5 V “A 76” Alkaline Batteries
Battery Life 150 hrs
Dimensions(L x W x H) Tester 16.3 x 4.5 x 3 cm
Boxed 24.5 x 13.5 x 4.5 cm
Weight Tester 90 g
Boxed 137 g

Ordering Information

Order No. Item
ECOECTESTHIGH Waterproof EcoTestr EC High Tester with ATC; 1 point Calibration

Conductivity Calibration Solutions

Order No. Item
ECCON2764BT 2764 μS KCL, 480 ml
ECCON1288BT 12.88 mS KCL, 480 ml

Download Brochure

• EcoTestr Series Family Brochure