Heating Baths (General)

Heating Baths (General)

Product Description

pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample

The selection of a suitable electrode depends on the types of application

Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable

Single Junction

Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers

Double Junction

Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes

Sealed(gel-filled)

No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required

Refillable

Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low

Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses

pH Electrodes (General Glass) & (General Plastic)

 

SKU: f001-1-1-2-1-3-1-1-1-2-1-2-1-1-1-1-1-1-2-1-2-2-2-1-1-2-1-1-1-1-1-1-1-1-1-1-1-1-2-2-1-1-1-3-1-1-1-2-1-1 Categories: ,

Description

Performance
  • Temperature range from ambient +7℃ to 100℃
  • Microprocessor PID control
  • Temperature calibration / Automatic tuning / Automatic run
Convenience
  • User friendly control panel
  • Bright VFD with membrane touch switch and control knob
  • Side handles for easy transportation
  • Dual wait on/off timer modes (1 min. to 99 hr. 59 min.)
  • Convenient memory function of up to three frequently set temperature
  • Corrosion-resistant stainless steel construction allowing other bath fluids as well as water and silicone fluids
  • Easy access drain valve for convenient handling
  • Low-profile design with sloped control panel for easier access and better safety
Safety
  • Isolated design of heater, and sensor by a baffle plate to protect users and samples against direct contact
  • Complete safety protection system with warning alarms
  • Low fluid level and dry-running, over-temperature, over-current
  • Control lock function prevents accidental changes during operation
  • Splash-proof keypad

Product Description

Model BW3-05G BW3-10G BW3-20G
Bath volume(L / cu ft) 3.5 / 0.1 11.5 / 0.4 20 / 0.7
Working temperature range (℃ / ℉) Amb. +7 to 100 / Amb. +12.6 to 212
Temperature stability 1) (±℃ / ℉) 0.4 / 0.72 0.3 / 0.54 0.3 / 0.54
Dimension (W×D×H) Bath opening / depth (W×L,D) (mm / inch) 240×136,150/9.4×5.4,5.9 300×240,200/11.8×9.5,7.9 498×300,200/19.6×11.8,7.9
Exterior (W×L×H) (mm / inch) 307×200×264/12.1×7.9×10.4 360×300×294/14.2×11.8×11.6 564×356×294/22.2×14×11.6
Net weight (Kg / lbs) 6.5 / 14.3 10 / 22 18.5 / 40.8
Electrical requirements (230V, 50 / 60Hz) 3A 4.3A 8.7A
Cat. No. AAH41305K AAH41315K AAH41325K

Ordering Information

Order No. Item
AAH41305K BW3-05G Heating Bath(3.5L), 230V, 50/60Hz
AAH41315K BW3-10G Heating Bath(11.5L), 230V, 50/60Hz
AAH41325K BW3-20G Heating Bath(20L), 230V, 50/60Hz

Optional accessories (Refer Brochure)

• Open-rings covers, Test tube racks• Spring wire racks, Half-shelf adjusters