pH 6+

Product Description

pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample

The selection of a suitable electrode depends on the types of application

Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable

Single Junction

Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers

Double Junction

Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes

Sealed(gel-filled)

No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required

Refillable

Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low

Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses

pH Electrodes (General Glass) & (General Plastic)

 

SKU: f001-1-1-2-1-3-1-1-1-2-1-2-1-1-1-1-1-1-2-1 Categories: ,

Description

  • Sturdy rubber boot protects the meter against accidental knocks
  • 3-point push button calibration
  • Choice of US, NIST and Pure low ionic pH buffer standards
  • Auto buffer recognition
  • Hold and auto-off functions
  • Self-diagnostic messages

Product Description

Product Specification Description
pH Range 0.00 to 14.00 pH
Resolution / Accuracy 0.01 pH / ± 0.01 pH
mV Range ±1000 mV
Resolution / Accuracy 0. 1 mV (±199.9mV ) ; 1 mV ( > ±199.9mV ) / ±0.2mV (± 199.9mV) ; ± 2 mV (>± 199.9mV)
Temperature Range 0.0 to 100.0 ºC
Resolution / Accuracy 0.1ºC / ± 0.5 ºC
No. of pH Calibration Up to 3 points
No. of pH Buffer Options USA (pH 4.01,7.00, 10.01)
NIST(pH 4.01, 6.86, 9.18)
PWB (pH 4,10, 6.97)
Electrode Included, general- purpose plastic body, single junction pH combination electrode, 12×90 mm, 1m cable length
Temperature Probe Included
Carrying case Yes
Power Requirements Included, 4 x 1.5 V ‘AAA’ batteries,
Mains operation not available
Dimensions
(L x W x H)
Meter 15.7 x 8.5 x 4.2 cm
Boxed 24 x 17 x 8 cm
Weight Meter 255 g
Boxed 555 g

Ordering Information

Order No. Item
ECPH602PLUSK pH 6+ pH/ORP Meter with single junction pH electrode ECFC7252101B, ATC probe & pH carrying kit set
ECFC7960101B General purpose plastic-body single junction gel-filled ORP Electrode, 12x90mm, BNC connector, 1m cable length

ORP Calibration Solutions

Order No. Item
ECORPQUIN Quinhydrone 263 mV, 480 ml
ECORPQUIN086 Quinhydrone 86 mV, 480 ml

pH Calibration Solutions

Order No. Item
ECBU4BTC pH 4.01 buffer, 480 ml
ECBU7BTC pH 7.00 buffer, 480 ml
ECBU10BTC pH 10.01 buffer, 480 ml
EC-BU-6.86BT pH 6.86 buffer, 480 ml
EC-BU-9.18BT pH 9.18 buffer, 480 ml