Photometer Tablet Reagents

Product Description

pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample

The selection of a suitable electrode depends on the types of application

Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable

Single Junction

Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers

Double Junction

Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes

Sealed(gel-filled)

No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required

Refillable

Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low

Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses

pH Electrodes (General Glass) & (General Plastic)

 

SKU: f001-1-1-2-1-3-1-1-1-2-1-2-1-1-1-1-1-1-2-1-2-2-2-1-1-2-1-1-1-1-1-1-1-1-1-1-1-1-2-2-1-1-1-3-1-1-1-2-1-1 Categories: ,

Description

Consumables for use with Palintest photometers, tablets supplied in blister packaging , provides an extremely easy means of analysis for an important range of water parameters

Browse our range of photometer reagents and standards below. The items are sub-categorized by instrument platform, and the tables display the parameter, measurement range and part code. Click the part code to access resources for that product

Product Description

Replacement Tablet Reagent Packs For Photometers

Reagent Order Code      (250 tablets) Order Code                  ( 50 tablets)
Alkalinity M (Alkaphot M) Range 0-500 mg/l (CaCO3) AP 250 PM 250
Alkalinity P (Alkaphot P) Range 0-500 mg/l (CaCO3) AP 251 PM 251
Alkalinity Total (Alkaphot) Range 0 – 500 mg/l (CaCO3) AP 188 PM 188
Aluminium Range 0-0.5 mg/l AP 166 PM 166
Ammonia Range 0 – 1.0 mg/l N AP 152 PM 152
Boron Range 0 – 2.5 mg/l B AP 190** PM 190
Bromine Range 0 – 10.0 mg/l AP 060 PM 060
Calcium Hardness (Calcicol) Range 0 – 500 mg/l CaCO3 AP 252 PM 252
Chloride (Chloridol) Range 0 – 50,000 mg/l NaCl AP 268 PM 268
Chlorine – Free (DPD 1)
Range 0 – 5 mg/l Cl2
AP 011 PM 011
Chlorine – Free, extended range (DPD 1)
Range 0 – 10.0 mg/l
AP 013 PM 013
DPD No 2 Phot (250F)
Range 0 – 5 mg/l Cl2
AP 021 PM 021
Chlorine – Free, Combined and Total
(DPD 1 and DPD 3) Range 0 – 5 mg/l Cl2
AP 031 PM 031
Chlorine – Total
(DPD 3 only)
Range 0 – 5 mg/l Cl2
AP 031/1
Chlorine – Free, Combined and Total, extended
range
(DPD No 1 and No 3)
Range 0 – 10.0 mg/l
AP 033 PM 033
Chlorine – Total, extended range (DPD 3 )
Range 0 – 10.0 mg/l
AP 033/1
Chlorine – Total
(DPD 4)
Range 0 – 5 mg/l Cl2
AP 041 PM 041
Chlorine HR Range 0 – 250 mg/l Cl2 AP 162 PM 162
Chlorine Dioxide (DPD) and Chlorite Range 0 – 10.0 mg/l AP 052 PM 052
Chlorine Dioxide (Lissamine Green B) LR Range 0 – 2.5 mg/l AP 064 PM 064
Chlorine Dioxide (Lissamine Green B) HR Range 2.5 – 20 mg/l AP 065 PM 065
Chromium VI (Chromicol) Range 0 – 1.0 mg/l AP 281 PM 281
Colour/Turbidity Range 10-500 (Hazen units) mg/l PM 269
Copper (Coppercol) Range 0 – 5 mg/l Cu AP 186 PM 186
Copper (Coppercol) Free only Range 0 – 5 mg/l Cu AP 187
Cyanuric Acid ( 250 tests )Range 0 – 200 mg/l AP 087 PM 087
DEHA Range 0 – 500 ppb DEHA AP 275 PM 275
Fluoride Range 0 – 1.5 mg/l F AP 179* PM 179
Hardness (Hardicol) Range 0 – 500 mg/l CaCO3 AP 254 PM 254
Hydrazine Range 0 – 0.5 mg/l N2H2 AP 103• PM 103†
Hydrogen Peroxide LR Range 0 – 2.0 mg/l H2O2 AP 104 PM 104
Hydrogen Peroxide HR Range 0 – 100 mg/l H2O2 AP 105 PM 105
Iron LR Range 0 – 1.0 mg/l Fe AP 155 PM 155
Iron HR Range 0 – 10 mg/l Fe AP 156 PM 156
Iron MR Range 0 – 5.0 mg/l Fe AP 292 PM 292
Magnesium Hardness (Magnecol) Range 0 – 500 mg/l CaCO3 AP 193 PM 193
Manganese Range 0 – 0.03 mg/l Mn AP 173 PM 173
Manganese HR Range 0 – 5 mg/l Mn AP 174 PM 174
Molybdate LR Range 0 – 20.0 mg/l MoO4 AP 258* PM 258
Molybdate HR Range 0 – 100 mg/l MoO4 AP 175 PM 175
Nickel (Nickeltest) Range 0 – 10.0 mg/l Ni AP 284* PM 284
Nitrate (Nitratest) Range 0 – 20.0 mg/l N AP 163* PM 163
Nitrite (Nitriphot) Range 0 – 1500 mg/l NaNO2 AP 260 PM 260
Nitrite (Nitricol) Range 0 – 0.5 mg/l N AP 109 PM 109
Organophosphonate (OP) Range 0 – 20.0 mg/l PO4 AP 262 PM 262
Ozone Range 0 – 2.0 mg/l O3 AP 056 PM 056
pH (Phenol Red) Range pH 6.8 – 8.4 AP 130 PM 130
Phenol (Phenoltest) Range 0 – 5.0 mg/l C6H5OH AP 287* PM 287
PHMB Range 0 – 100 mg/l active biocide AP 272 PM 272
Phosphate LR Range 0 – 4 mg/l PO4 AP 177* PM 177
Phosphate HR Range 0 – 100 mg/l PO4 AP 114 PM 114
Potassium Range 0 – 12 mg/l K AP 189 PM 189
Silica  Range 0 – 4.0 mg/l SiO2 AP 181* PM 181
Silica HR Range 0 – 150 mg/l SiO2 AP 290* PM 290
Sulphate Range 0 – 200 mg/l SO4 AP 154 PM 154
Sulphide Range 0 – 0.5 mg/l S AP 168* PM 168
Sulphite (Sulphitest) Range 0 – 500 mg/l Na2SO3 AP 266 PM 266
Zinc Range 0 – 4 mg/l Zn AP 148 PM 148