Thermo Reactor COD Analysis – 25 Positions

///Thermo Reactor COD Analysis – 25 Positions

Thermo Reactor COD Analysis – 25 Positions

Product Description

pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample

The selection of a suitable electrode depends on the types of application

Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable

Single Junction

Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers

Double Junction

Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes

Sealed(gel-filled)

No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required

Refillable

Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low

Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses

pH Electrodes (General Glass) & (General Plastic)

 

SKU: f001-1-1-2-1-3-1-1-1-2-1-2-1-1-1-1-1-1-2-1-2-2-2-1-1-2-1-1-1-1-1-1-1-1-1-1-1-1-2-2-1-1-1-3-1-1-1-2-1-1 Categories: ,

Description

25 position thermo reactors for Chemical Oxygen Demand (COD) with settable temperature (70, 100, 120, 150, 160 °C) and operating time (30, 60, 120 minutes or continuous)

Accurate Control

      • 5 preset temperatures – 70, 100, 120, 150 and 160 °C
      • 4 analysis times – 30 , 60, 120 minutes or continuous
      • LED indicator of operation

Choice of Size

      • ECO 25 can process 25 samples in Ø 16 mm test tubes simultaneously

Economical Operation

      • COD analysis in only 30 minutes at 160 °C
      • 16 mm diameter tubes minimize reagent consumption

Safety Assured

      • Automatic shut-down at run end
      • Acoustic signals, e.g., at shut-down
      • Antisplash cover protects the user
      • Test tube extractor removes all tubes without user contact Rapid ID through
        alphanumeric labeling

Product Description

Product Specification Description
Construction material Epoxy painted metal structure
Models 25 pos. (Ø16 mm)
Set temperature display visualization
Countdown display visualization
End of the cycle acoustic signal with automatic switch-off
Power 400 W
Weight 3.8 Kg (8.4 lb)
Dimensions (WxHxD) 155x95x275 mm (6.1×3.7×10.8 in)

 

PERFORMANCE

Selectable working temperatures 70, 100, 120, 150 and 160
Selectable working times 30, 60, 120 or continuous

 

HEATING BLOCK TECHNICAL DATA

Temperature stability ± 0.5 °C
Temperature homogeneity ± 0.5 °C
Temperature precision ± 1 °C
Over temperature safety

SIGNALS

Reaching of set temperature acoustic and visual signal
Countdown visual signal
End of cycle acoustic and visual signal
Probe interruption acoustic and visual signal
Broken probe acoustic and visual signal
Exceed temperature range acoustic and visual signal

Ordering Information

Order No. Item
ECO 25 – F101A0125 ECO 25 Thermo reactor 115-230 V / 50-60 Hz

Accessories

A00001039 Test tubes extractor
CA0091636 Holder for 12 round glass cells