V-600N

Product Description

pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample

The selection of a suitable electrode depends on the types of application

Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable

Single Junction

Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers

Double Junction

Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes

Sealed(gel-filled)

No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required

Refillable

Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low

Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses

pH Electrodes (General Glass) & (General Plastic)

 

SKU: f001-1-1-2-1-3-1-1-1-2-1-2-1-1-1-1-1-1-2-1-2-2-2-1-1-2-1-1-1-1-1-1-1-2-2 Categories: ,

Description

  • 70* 40 mm blue-lit LCD displays T, A, C, K, B
  • Adjust automatically 0%A and 100%T
  • Large sample compartment can accommodate 5-100mm path length cuvettes
  • Can make test of Quantitative and Kinetics with professional PC software
  • Light source tungsten lamp, manual wavelength setting
  • Store 50 groups of measuring data and 10 groups of K & B value

 

Product Description

Specifications AN-V-600N
WL range 320~1100 nm
Spectrum bandwidth  4 nm
WL accuracy 2 nm
WL repeatability 1 nm
Photometric Accuracy  0.5% T
Photometric Repeatability 0.2% T
Stray light 0.15% T @500 nm
Stability 0.002 A@500 nm
Wavelength Setting manual
Light Source Tungsten lamp
Display 70 * 40 mm blue-lit LCD
Detector Silicon Photodiode
Output USB port or RS232 port
Power AC 220V/50Hz
Dimension 520*450*320 mm
Weight 10 kg

Ordering Information

Order No. Item
AN-V-600N Economical Visible Spectrophotometer with glass cuvette 10mm (1 set of 4), software , power cord AC 220V/50Hz