• Product Description

    pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample The selection of a suitable electrode depends on the types of application Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable
    Single Junction
    Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers
    Double Junction
    Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes
    Sealed(gel-filled)
    No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required
    Refillable
    Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses pH Electrodes (General Glass) & (General Plastic)  
  • Product Description

    pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample The selection of a suitable electrode depends on the types of application Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable
    Single Junction
    Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers
    Double Junction
    Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes
    Sealed(gel-filled)
    No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required
    Refillable
    Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses pH Electrodes (General Glass) & (General Plastic)  
  • Product Description

    pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample The selection of a suitable electrode depends on the types of application Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable
    Single Junction
    Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers
    Double Junction
    Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes
    Sealed(gel-filled)
    No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required
    Refillable
    Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses pH Electrodes (General Glass) & (General Plastic)  
  • Product Description

    pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample The selection of a suitable electrode depends on the types of application Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable
    Single Junction
    Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers
    Double Junction
    Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes
    Sealed(gel-filled)
    No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required
    Refillable
    Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses pH Electrodes (General Glass) & (General Plastic)  
  • Product Description

    pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample The selection of a suitable electrode depends on the types of application Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable
    Single Junction
    Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers
    Double Junction
    Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes
    Sealed(gel-filled)
    No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required
    Refillable
    Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses pH Electrodes (General Glass) & (General Plastic)  
  • Product Description

    pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample The selection of a suitable electrode depends on the types of application Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable
    Single Junction
    Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers
    Double Junction
    Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes
    Sealed(gel-filled)
    No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required
    Refillable
    Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses pH Electrodes (General Glass) & (General Plastic)  
  • Product Description

    pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample The selection of a suitable electrode depends on the types of application Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable
    Single Junction
    Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers
    Double Junction
    Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes
    Sealed(gel-filled)
    No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required
    Refillable
    Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses pH Electrodes (General Glass) & (General Plastic)  
  • Product Description

    pH measurement is usually done with the use of a combination electrode. The combination electrode is an electrode system formed by a glass sensing half-cell and an internal reference half-cell. As the reference junction acts as the medium of conductor between the reference electrolyte and the sample to be measured, it must allow free movement of electrons through the junction and into the sample The selection of a suitable electrode depends on the types of application Eutech’s pH /ORP combination electrodes offer the convenience of having the reference and measuring electrodes combined in a single housing. They are offered in a variety of configurations to suit most laboratory and field application needs. Choose from two models: single-or double-junction, sealed (gel-filled) or refillable
    Single Junction
    Ideal for general-purpose applications. Ag+ ions are in contact with junction and this can cause chemical interaction with sulphur. Not suitable for biological samples or tris buffers
    Double Junction
    Prevents interference between the inner fill solution and sample. Electrolyte is free of Ag+ ions. Suitable for use with biological samples. Can be used in place of calomel reference electrodes
    Sealed(gel-filled)
    No refill hole. The reference electrolyte is usually a gel. Replacement of the electrode is necessary when it gets contaminated. Virtually no maintenance is required
    Refillable
    Refill hole allows reference electrolyte replenishment. Can be used many times over. Needs refilling when fill solution is low Choose single junction ORP electrodes for field, clean water, and other general-purpose applications or double junction electrodes for samples containing heavy metals and organics. Platinum sensors are suitable for most general uses pH Electrodes (General Glass) & (General Plastic)  
    • Backlit, rugged waterproof meter is ideal for any environment
    • Durable waterproof and dustproof design with IP67 rating
    • Large, backlit display – View measurement with temperature and % slope
    • Grip-Clip™ – Quickly and easily secures the pH electrode to your beaker or container
    • Auto buffer recognition – Automatically identifies the correct pH buffer for rapid calibration
    • Calibration due alarm – Set a visible reminder when it is time to recalibrate the meter
    • Ready indicator, manual or automatic measurement hold feature and optional automatic shutoff function
    • Intuitive, user-friendly icons – Electrode status displays pH slope
    • Store up to 500 data sets – Easy USB or RS232 output with optional data cables
    • Built-in real-time clock stamps stored data and calibration data with time and date – Meets standards for GLP (Good Laboratory Practices)
    • Extended battery life from two AA batteries, or use optional universal power adapter
    • Compatible with pH, ORP or ISE electrodes having a BNC connector

    Product Description

    Product Specification Description
    pH Range -2.00 to 16.00 pH
    Resolution / Accuracy 0.01 pH / ± 0.01 pH
    pH Calibration Points Up to 5 points (USA & NIST & CUSTOM) Up to 6 points (DIN)
    mV Range ± 2000 mV
    Resolution / Accuracy 0.1 mV ± 999.9 mV; 1 mV beyond/±0.2 mV + 2 LSD or + 0.5 % of reading; whichever is greater
    mV Calibration Points ± 200 mV
    Ion Range 0.0 to 2000 ppm
    Resolution / Accuracy 0.01 / 0.1 / 1 ppm / ± 0.5 % full scale (monovalent); ±1 % full scale (divalent)
    Ion Calibration Points From 2-4 or 2-5 points: 0.10, 1.00, 10.0, 100.0 & 1000 /0.20, 2.00, 20.0, 200.0 & 2000 / 0.50, 5.00, 50.0 & 500.0
    Temperature Range -10.0 to 110.0 ºC (14.0 to 230.0 ºF)
    Resolution / Accuracy 0.1 ºC/ ºF / ± 0.5 ºC; ± 0.9 ºF
    Temperature Calibration Points Offset in 0.1 increments, ± 10 ºC or ± 18 ºF
    Display Three line custom LCD
    Temperature Compensation Automatic or manual from -10 to 110 ºC
    Memory Stores up to 500 data sets
    Power Two AA batteries (included), >500 hours (without backlight),  AC adapter (optional)
    Output USB or RS232
    Real-Time Clock Time and date stamp on calibration and stored data
    Standard supply Meter Kit with double-junction pH electrode ECFC7252201B and ATC probe, Grip-Clip™, two AA batteries, hard carry case, USB cable, pH buffers, storage solution ,rinse solution
    Dimensions (L x W x H) Meter 77/8” x 31/8” x 21/4” (20 x 8.3 x 5.7 cm) Boxed 91/8” x 91/8” x 23/4” (23 x 23 x 7 cm)
    Weight Meter 1 lb (0.5 kg) Boxed 1.4 lb (0.7 kg)

    Ordering Information

    Order No. Item
    ECPHWP45002K pH 450 meter Kit with double-junction pH electrode ECFC7252201B and ATC probe, Grip-Clip™, two AA batteries, hard carry case, USB cable, pH buffers, storage solution, rinse solution
    60X426401 Optional 100 / 240 VAC SMPS power adapter, 9 V, 6 W
    ECFC7960201B General purpose plastic-body double junction gel-filled ORP Electrode, 12x90mm, BNC connector, 1m cable length
    ECFC7960101B General purpose plastic-body single junction gel-filled ORP Electrode, 12x90mm, BNC connector, 1m cable length

    pH Calibration Solutions

    Order No. Item
    ECBU1BT pH 1.68 buffer, 480 ml
    ECBU4BTC pH 4.01 buffer, 480 ml
    ECBU7BTC pH 7.00 buffer, 480 ml
    ECBU10BTC pH 10.01 buffer, 480 ml
    ECBU12BT pH 12.45 buffer, 480 ml
    EC-BU-6.86BT pH 6.86 buffer, 480 ml
    EC-BU-9.18BT pH 9.18 buffer, 480 ml

    ORP Calibration Solutions

    Order No. Item
    ECORPQUIN   Quinhydrone 263 mV, 480 ml
    ECORPQUIN086  Quinhydrone 86 mV, 480 ml

    Download Brochure

    • Eutech 150 & 450 Series Family Brochure
    • Large, comprehensive screen that displays readings, calibration points and electrode indicator
    • Ready indicator alerts when readings are stable
    • Up to 6 point push button calibration with auto-buffer recognition
    • Non-volatile memory holds up to 100 data points
    • Integral electrode holder

    Product Description

    Product Specification Description
    pH Range -2.000 to 20.000 pH
    Resolution/Accuracy 0.1 / 0.01/ 0.001 pH (selectable)/ ± 0.002 pH + 1 LSD
    ORP Range ± 2000 mV
    Resolution/Accuracy 0.1 mV / ± 0.2 mV
    Temp.Range 0.0 to 100.0ºC (32.0 to 212.0ºF)
    Resolution/Accuracy 0.1 ºC (0.1  ºF) / ± 0.3 ºC / ± 0.5 ºF (0 to 70 ºC)
    ATC/MTC 0 to 100 ºC (pH only)
    Buffer Options USA, NIST, DIN, User 1, User 2, Custom
    No.of pH Calibration Points 6 points
    Built-in Electrode Arm Yes
    Memory 500 data sets
    GLP Yes
    Input DC socket, BNC, 2.5 mm phono (ATC), phono (reference), phono (RS232)
    Output RS 232C (via cable)
    Printer Included AN-270 ,Brand Antech dot matrix printer
    Electrode Included EC620131, glass body, combination pH electrode, open pore, gel filled, 12×120 mm, BNC connector, 1m cable length. ORP electrode to be ordered separately
    Temp.Probe Included PH5TEMB01P
    Power Requirements Included, 100 /240VAC SMPS power adapter, 9V,6W
    Dimensions (L x W x H) Meter 17.5 x 15.5 x 6.9 cm Boxed 30.8 x 23.5 x 12.4 cm
    Weight Meter 650 g Boxed 1800 g

    Ordering Information

    Order No. Item
    ECPH27005E-P pH 2700 meter with glass body, open pore pH electrode EC620131, ATC Probe PH5TEMB01P, integral electrode holder , 100/240 VAC Adapter, RS232 cable and AN-270 Dot Matrix Printer
    ECFC7960201B General purpose plastic-body double junction gel-filled ORP Electrode, 12x90mm, BNC connector, 1m cable length
    ECFC7960101B General purpose plastic-body single junction gel-filled ORP Electrode, 12x90mm, BNC connector, 1m cable length

    pH Calibration Solutions

    Order No. Item
    ECBU1BT pH 1.68 buffer, 480 ml
    ECBU4BTC pH 4.01 buffer, 480 ml
    ECBU7BTC pH 7.00 buffer, 480 ml
    ECBU10BTC pH 10.01 buffer, 480 ml
    ECBU12BT pH 12.45 buffer, 480 ml
    EC-BU-6.86BT pH 6.86 buffer, 480 ml
    EC-BU-9.18BT pH 9.18 buffer, 480 ml

    ORP Calibration Solutions

    Order No. Item
    ECORPQUIN Quinhydrone 263 mV, 480 ml
    ECORPQUIN086 Quinhydrone 86 mV, 480 ml

    Download Brochure

    • Eutech pH 70042GS ,pH 27005E ,pH 27005E-P Brochure
    • Up to 6-point calibration with auto-buffer recognition
    • Non-volatile memory holds up to 500 data points-time and date-stamped for GLP compliance
    • Cal-due alarm-no more out-dated calibrations
    • Bi-directional RS232 for easy data transfer to computer
    • Password protection for setup and calibration

    Product Description

    Product Specification Description
    pH Range -2.000 to 20.000 pH
    Resolution/Accuracy 0.1 / 0.01/ 0.001 pH (selectable)/ ± 0.002 pH + 1 LSD
    ORP Range ± 2000 mV
    Resolution/Accuracy 0.1 mV / ± 0.2 mV
    Temp.Range 0.0 to 100.0 ºC (32.0 to 212.0 ºF)
    Resolution/Accuracy 0.1 ºC (0.1 ºF) / ± 0.3 ºC / ± 0.5 ºF (0 to 70 ºC)
    ATC/MTC 0 to 100 ºC (pH only)
    Buffer Options USA, NIST, DIN, User 1, User 2, Custom
    No.of pH Calibration Points 6 points
    Built-in Electrode Arm Yes
    Memory 500 Data sets
    GLP Yes
    Input DC socket, BNC, 2.5 mm phono (ATC), phono (reference), phono (RS232)
    Output RS 232C (via cable)
    Printer
    Electrode Included EC620131, glass body, combination pH electrode, open pore, gel filled, 12×120 mm, BNC connector, 1m cable length. ORP electrode to be ordered separately
    Temp.Probe Included PH5TEMB01P
    Power Requirements Included, 100 /240VAC SMPS Power Adapter, 9V,6W
    Dimensions (L x W x H) Meter 17.5 x 15.5 x 6.9 cm Boxed 30.8 x 23.5 x 12.4 cm
    Weight Meter 650 g Boxed 1800 g

    Ordering Information

    Order No. Item
    ECPH27005E pH 2700 meter with glass body, open pore pH electrode EC620131, ATC Probe PH5TEMB01P, integral electrode holder , 100/240 VAC Adapter and RS232 cable
    ECFC7960201B General purpose plastic-body double junction gel-filled ORP Electrode, 12x90mm, BNC connector, 1m cable length
    ECFC7960101B General purpose plastic-body single junction gel-filled ORP Electrode, 12x90mm, BNC connector, 1m cable length

    pH Calibration Solutions

    Order No. Item
    ECBU1BT pH 1.68 buffer, 480 ml
    ECBU4BTC pH 4.01 buffer, 480 ml
    ECBU7BTC pH 7.00 buffer, 480 ml
    ECBU10BTC pH 10.01 buffer, 480 ml
    ECBU12BT pH 12.45 buffer, 480 ml
    EC-BU-6.86BT pH 6.86 buffer, 480 ml
    EC-BU-9.18BT pH 9.18 buffer, 480 ml

    ORP Calibration Solutions

    Order No. Item
    ECORPQUIN Quinhydrone 263 mV, 480 ml
    ECORPQUIN086 Quinhydrone 86 mV, 480 ml

    Download Brochure

    • Eutech pH 70042GS ,pH 27005E ,pH 27005E-P Brochure
    • Up to 6-point calibration with auto-buffer recognition
    • Quick, easy electrode diagnosis with multiple pH slopes and offset display
    • Non-volatile memory holds up to 500 data points – time and date-stamped for GLP compliance
    • Calibrate with up to 5 custom pH buffers – use any pH values that are ≥1.0 pH unit apart
    • Cal-due alarm – no more out-dated calibrations
    • Auto-logging function for convenient continuous monitoring
    • Password protection for setup and calibration

    Product Description

    Product Specification Description
    pH Range -2.000  to  20.000 pH
    Resolution/Accuracy 0.1 / 0.01/ 0.001 pH (selectable) /± 0.002 pH + 1 LSD
    mV Range ± 2000 mV
    Resolution/Accuracy 0.1 mV / ± 0.2 mV
    Temp.Range 0.0 to 100.0 ºC / 32.0 to 212.0 ºF
    Resolution/Accuracy 0.1 ºC (0.1 ºF) / ± 0.3 ºC (0.5 ºF)
    ATC Yes (0 to 100 ºC)
    No.of pH Calibration Points 6 points
    Buffer Sets USA, NIST, DIN, User 1, User 2, Custom
    Built-in Electrode Arm Yes
    GLP Yes
    Memory 500 data sets
    Output RS 232C (via cable)
    Electrode Included ECFG7370101B, Single junction glass pH electrode, ATC Probe (PH5TEMB01P). ORP electrode to be ordered separately
    Temp.Probe Included
    Power Requirements Included, 100 /240VAC SMPS Power Adapter , 9V,6W
    Dimensions (L x W x H) Meter 17.5 x 15.5 x 6.9 cm Boxed 30.8 x 23.5 x 12.4 cm
    Weight Meter 650 g Boxed 1800 g

    Ordering Information

    Order No. Item
    ECPH270042GS Eutech pH 2700 Meter With pH Electrode (ECFG7370101B), ATC Probe (PH5TEMB01P), Integral Electrode Holder, 100/240 VAC Adapter, RS232 cable, & pH Electrode Refill Solution
    ECFC7960201B General purpose plastic-body double junction gel-filled ORP Electrode, 12x90mm, BNC connector, 1m cable length
    ECFC7960101B General purpose plastic-body single junction gel-filled ORP Electrode, 12x90mm, BNC connector, 1m cable length

    pH Calibration Solutions

    Order No. Item
    ECBU1BT pH 1.68 buffer, 480 ml
    ECBU4BTC pH 4.01 buffer, 480 ml
    ECBU7BTC pH 7.00 buffer, 480 ml
    ECBU10BTC pH 10.01 buffer, 480 ml
    ECBU12BT pH 12.45 buffer, 480 ml
    EC-BU-6.86BT pH 6.86 buffer, 480 ml
    EC-BU-9.18BT pH 9.18 buffer, 480 ml

    ORP Calibration Solutions

    Order No. Item
    ECORPQUIN Quinhydrone 263 mV, 480 ml
    ECORPQUIN086 Quinhydrone 86 mV, 480 ml

    Download Brochure

    • Eutech 2700 Series Family Brochure